5-Amino-1MQ

Certificate of Analysis & Complete Test Results

✓ Verified & Certified
Test Date
Jan 30, 2026
Batch Number
130079
Purity Level
99.91%

Certificate of Analysis

High-Performance Liquid Chromatography

Client: Peptides Canada
Sample Name: Cerebrolysin
Batch #: 130079
Report Date: 09/02/2025
Test: Purity
Receipt Date: 08/31/2025
Analysis Date: 09/02/2025
Matrix: Powder
Number of samples: 1
Purity: 99.91%

Research-grade specification: ≥95.0% — this batch exceeds specification.

Date File 130079_MS2_posneg_Cerebrolysin_Lot130079_purity.d Sample Name Cerebrolysin_Lot130079_purity
Sample Type Sample Position P8-53
Instrument Name LCMS-7800 Series Username -
Acq Method Cerebrolysin_purity_60mg.m Acquired 09/02/2025 10:14:58 AM
IRM Calibration Status Calibrated Time (UTC-07:00)
Comment Sample test for purity of Cerebrolysin batch 130079 Multiple small Peptides detected: data represents the dominant peptide fraction DA Method SignalToNoiseCheckout.m
Sample Group Test Batch 4 Info. -
Stream Name LC1 Acquisition 09/02/2025 10:14:58 AM
Acquisition SW Version 6400 Series Triple Quadrupole B.09.00 (89037.0) Time (Local) (UTC-07:00)

Peak List

Time Area % Area
5.02 min 5081.7 99.91 %
6.73 min 56.1 0.09 %

* determined as Cerebrolysin based on retention time

Note: Percent area between two compounds is not quantitative due to variable extinction coefficients.

Test Screen

UV Chromatogram:

Identity: Cerebrolysin

(Other names: Cerebrolysin, FPF-1070)

CAS: 12656-61-0

Data

Mass Spectrum

MSMS ID — head to tail database matching

Mass Spectrum Mixed Peptide Envelope encompasses the 2-6 positive change states conferring Peptide Mass

Cerebrolysin

Expected Mass: 2850.6

Observed Mass: 2850.58

Reviewed and approved by:

Herman Lelie